Feature | Part No. | Description | Requirements | |
FollowMe™ force-based positioning | SF008 | Position the crosshead by manually pushing or pulling on the force gauge shaft or load cell. Increasing force produces greater speeds. Ideal for setups and quick positioning. |
|
|
Travel indication | SF009 | Position is indicated on the control unit display, with output via USB. An internal scale utilizing Renishaw technology produces significantly higher accuracy than with conventional rotary encoder-based designs. Backlash and nonlinearity are virtually eliminated. |
|
|
Computer control | SF010 |
Fully control the stand and force gauge / indicator via custom-written application in any language supporting ASCII communications. Also responds to the legacy Chatillon TCD command set and legacy Nexygen TCD software (not available from Mark-10). This option is not required for MESUR®gauge Plus software. |
|
|
Programmable travel limits | SF011 | The stand stops at or cycles between programmable upper and lower travel distances. |
|
|
Overload protection | SF012 | Protects a force gauge or force sensor against overload. Also compatible with many competitors’ gauges. |
|
|
Auto return | SF013 | The crosshead moves to a limit switch, force set point, travel position, or break, then stops and reverses direction at full speed to the opposite limit. |
|
|
Cycling / dwell time | SF014 | Same as auto-return, but programmable up to 99,999 cycles. Programmable dwell time at upper and lower limits up to 9,999 seconds. |
|
|
Independent Up and Down speeds | SF016 | Individually specify speeds for the up and down directions. |
- |
|
Low speed extension | SF017 | Extends the standard speed range down to 0.001 in/min (0.02 mm/min). |
- |
|
High speed extension |
SF018 SF018-1 |
ESM1500 / ESM1500S: Extends max speed to 90 in/min (2,300 mm/min). ESM750 / ESM750S: Extends max speed to 60 in/min (1,525 mm/min). |
- |
|
Break detection | SF019 | Crosshead stops at a programmable drop in force. |
|
|
Loadholding | SF020 | Dynamically adjusts the crosshead position to maintain a specified load for an indefinite or specified period of time. |
|
|
Preload / sample touch | SF021 | Stops the crosshead and/or zeroes the travel display at an initial preload - useful in tensile, spring, elongation, and other applications. |
|
|
Profiles | SF022 | Save and recall sets of test parameters, such as speeds, travel limits, preload, etc. Maximum of 50 profiles may be stored. | - | |
Complete options package |
SFCOMP (ESM1500 / ESM750) SFCOMP-1 (ESM1500S / ESM750S) |
Includes all functions listed above. Requires a Series 7 or 5 gauge or indicator |
Máy đo độ căng dây đai - máy đo độ căng dây cáp Mark 10
- AT2E
- As Scholer
- AMETEK LAND
- Bircher
- Barksdale
- Beckhoff
- Bussmann
- Baumuller
- Burkert
- Bihl-wiedemann
- CEIA
- CEMB
- Elau
- Daiichi Electronics
- ECDI
- Fireye
- Flow meter
- Gemu
- Gastron
- IBA
- keller
- Knick
- Kiepe
- Kyowa
- Koganei
- Lapar
- Mark-10
- Matsushima
- Matsui
- Masibus
- Maxonic
- Minimax
- Nireco
- OHKURA
- PILZ
- PILZ
- Pora
- Pentair
- Puls
- PCI Instrument
- Red lion
- STI Vibration Monitoring
- Teclock
- TDK lambda
- Van der Graaf
- valpes
- Wise
- Wago
- Wittenstein
-
Watanabe
- Bộ cách ly tín hiệu
- Bộ chia - Distributors
- Bộ chuyển đổi tín hiệu nhiệt độ
- Bộ chuyển đổi tín hiệu cảm biến
- Bộ chuyển đối tín hiệu điện áp
- Bộ chuyển đổi tín hiệu xung
- Thiết bị báo động
- Mô đun tính toán hiệu chỉnh
- Mô đun mở rộng
- Bộ chuyển đổi xoay chiều và một chiều
- Bộ tạo tín hiệu
- Bộ chuyển đổi tín hiệu truyền thông
- Bộ Khuếch đại cách ly tín hiệu
- YOUNG TECH
- Một số hãng khác
- BRAND OTHER
- TAKENAKA
- Tema
- Comet Systems
- Spohn Burkhardt
- Schenck Process
-
Trực tuyến:1
-
Hôm nay:540
-
Tuần này:540
-
Tháng trước:12757
-
Tất cả:2570317